NurApiSetCustomHoptableEx Method

Set pre-built, extended custom hop table (+LBT threshold and maximum TX level).

Definition

Namespace: NurApiDotNet
Assembly: NordicID.NurApi.Net (in NordicID.NurApi.Net.dll) Version: 4.0.0
C#
public void SetCustomHoptableEx(
	uint[] freqArr,
	uint nChan,
	uint chTime,
	uint pauseTime,
	uint lf,
	uint Tari,
	int lbtThresh,
	uint maxTxLevel
)

Parameters

freqArr  UInt32
Array of generated frequencies. Values are in kHz, range is 840000...960000. Must be disvisible by 25. Number of frequencies is 1...MAX_CUSTOM_FREQS and it must match the nChan parameter.
nChan  UInt32
Number of channels in freqArr.
chTime  UInt32
Channel time in milliseconds. Minimum is 100.
pauseTime  UInt32
Pause time between channel change in milliseconds. Maximum is 1000.
lf  UInt32
Maximum link frequency. Valid values are 160000, 256000 and 320000.
Tari  UInt32
Tari setting: 1 = 12.5us, 2=25us. Other are invalid.
lbtThresh  Int32
LBT threshold value in dBm, if used. Minimum value is -90.
maxTxLevel  UInt32
Maximum TX level. Range is 0...19.

See Also